BioSqueeze Inc. has helped oil and gas operators across the country solve seemingly impossible problems, sealing methane leaks after several failed attempts with other materials. Read the proof here, with reports on how BioSqueeze® has been successfully applied in a variety of situations.
May 21, 2024
A Deep Penetrating Annular Surface (DPAS™) BioSqueeze® was used to eliminate annular gas leaking from a plugged orphan well in Cleveland, OH as part of the ODNR's orphan well plugging program....
Application:
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Feb 06, 2024
DPAS was used to eliminate annular pressure on the 16” x 20 (155 psi) and 20” x 30” (150 psi) annuli on an injection well being abandoned in Wyoming....
Application:
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Aug 22, 2023
BSI eliminated gas on a storage well being abandoned in Virginia by performing a Deep Penetrating Annular Surface (DPAS) BioSqueeze®...
Application: P&A
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Aug 12, 2023
BSI re-entered a plugged well in Ohio to eliminate gas on the intermediate casing, which continued to leak after multiple attempts with alternative sealing technologies....
Application: P&A
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Jan 12, 2023
BSI was contracted to assist with gas migration on a re-entry in Wyoming. Existing cement plugs prevented access for a perf and squeeze without drillout, prompting the operator to explore alternative remediation techniques. BSI utilized DPAS to push fluids directly into leakage pathways in the annulus from surface....
Application: P&A
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Oct 12, 2022
BSI was contracted to mitigate annular gas on a well in Pennsylvania leaking from the 8-5/8” x 5-1/2” annulus. The well was prepared by cutting two narrow 360 degree sand notches at around 1,400’ through the 5-1/2” casing, installing 2-3/8” tubing to the depth of the bottom notch, and setting a bridge plug just below the bottom notch....
Application: P&A
Job Type: Downhole BioSqueeze®
Sep 20, 2022
BSI was contracted to eliminate annular pressure on a well in Pennsylvania where previous remediation had failed. A 0 psi log showed no bond above 2,200’, while a 2,500 psi log indicated better bonding around 2,100’ due to prior treatment with a casing expansion tool....
Application: P&A
Job Type: Downhole BioSqueeze®
Sep 12, 2022
BSI was contracted to mitigate casing pressure on a well in Pennsylvania. The bond log indicated poor cement bonding throughout the well. Prior to our arrival an unsuccessful attempt to cut and pull the 5-1/2” casing was made....
Application: P&A
Job Type: Downhole BioSqueeze®
Sep 06, 2022
BioSqueeze Inc. was contracted to remediate bradenhead pressure on a well in the process of being abandoned in Colorado. Cement had been squeezed lower previously, but annular pressure remained....
Application: P&A
Job Type: Downhole BioSqueeze®
Aug 30, 2022
BSI was contracted to reduce bradenhead pressure on a producing well in Colorado. Bond logs indicated there was a micro annulus behind the 5-1/2” production casing....
Application: Producing
Job Type: Downhole BioSqueeze®
Aug 17, 2022
BSI was contracted to eliminate gas migration on the backside of the 7” casing of a well being plugged in Pennsylvania. Bond logs indicated good cement, so a noise-temp log was used to identify the shallowest gas source (600’)....
Application: P&A
Job Type: Downhole BioSqueeze®
Aug 10, 2022
BioSqueeze Inc. was contracted to mitigate annular gas on the 13-3/8 in x 9-5/8 in annulus on a previously plugged well in Ohio that multiple other attempts with cement, resin, etc. had failed to fix....
Application: P&A
Job Type: Downhole BioSqueeze®
Jul 22, 2022
BioSqueeze Inc. was contracted by an operator in Ohio to eliminate annular pressure in a well in the process of being retired. The well was leaking from the 13-3/8 in x 9-5/8 in annulus and had several cement plugs in the wellbore, preventing downhole access for a standard perf and squeeze....
Application: P&A
Job Type: Deep Penetrating Annular Surface (DPAS) BioSqueeze®
Jul 21, 2022
BioSqueeze Inc. was contracted by an operator in Colorado to eliminate bradenhead pressure in a well slated for abandonment. Prior to our arrival, the well was prepared by perforating at 2,880 ft (gas source), 2,270 ft (channeling), and 870 ft (50 ft below surface casing shoe) through the 4-1/2 in casing string....
Application: P&A
Job Type: Downhole BioSqueeze®
Jul 14, 2022
BioSqueeze Inc. was contracted by an operator to seal a leaking annulus in a well in the process of being abandoned. Previous attempts to seal the leak had little to no impact....
Application: P&A
Job Type: Downhole BioSqueeze®
Mar 09, 2022
BioSqueeze Inc. was contracted by an operator in the DJ Basin of Colorado to remediate high bradenhead pressure (sustained casing pressure) On four of their horizontal producing wells....
Application: Producing
Job Type: Downhole BioSqueeze®